Item name |
Measurement range |
Accuracy |
Explanation: |
Voltage/ current/ frequency |
Three-phase voltage: 10 – 700V (true RMS)
Neutral line voltage: 1~70V (true RMS)
Three-phase current: 0.5~1000A (true RMS 1000A current sensor is optional)
Neutral line current: 0~25A (true RMS 25A current sensor is optional)
Frequency: 30~80Hz |
Voltage: ±0.5%
Current: ±0.5%
Frequency: ±0.01Hz |
Here the phase A voltage frequency is used as the measurement frequency |
|
Harmonic measurement |
Voltage harmonics: total harmonics +1 ~ 50th harmonics.
Current harmonics: total harmonics +1 ~ 50th |
Voltage harmonics: ±0.1(%f)
Current harmonics: ±0.05(A) |
|
Power measurement |
Active power: 0.05~700KW
Apparent power: 0.05~700KVA
Reactive power: 0.05~700KVAR
Power factor: 0.00~1.00
Active electric energy: 0.01~10000kWh
Apparent electric energy: 0.01~10000kVAh
Reactive electric energy: 0.01~10000kVARh
Average power factor: 0.00~1.00 |
Reactive power: reading ±2%
Power factor: reading ±0.005%
Active electric energy: reading ±2%
Apparent electric energy: reading ±2%
Reactive electric energy: reading ±2%
Average power factor: reading ±2% |
|
Three phase un-balance |
Fundamental voltage: 10 ~ 700V (true RMS)
Fundamental current: 0.5 ~ 1000A (true effective value)
Fundamental frequency: 40 ~ 70Hz
Phase angle: 0 ~ 360 °
Unbalance: 0.0% ~ 100% |
Voltage: 0.5%;
Current: 0.5%
Frequency: reading ± 0.01Hz
Phase angle: reading ± 0.3 °
Voltage unbalance: reading ± 0.2
Current unbalance: reading ± 0.2 |
Here the phase A voltage frequency is used as the total measurement frequency |
Monitoring records |
Recordable parameters:
Three-phase voltage three-phase current neutral current voltage harmonics (total harmonics 1~25th harmonic) current harmonics (total harmonic 1~25th harmonic) three-phase unbalance active power power factor fluctuation flicker |
Recordable time = (the maximum number of data that can be recorded by the instrument times save time interval)/60 mins=18635*3s/3600s=15.5h
Storage interval: 3s-30min~ |
The collection interval is set to 3s which can monitor 15.5 hours and the collection interval is set to 30 min which can monitor 388 days (3s to 30 min continuously adjustable) |
Sudden rise and fall |
Sudden voltage rise voltage fall and temporary power failure |
|
Up to 40 events can be recorded |
Fluctuation |
Voltage fluctuation amount: 0.1%~10.0% |
Measurement error £ ±5% |
|
Flicker |
Short-term flicker
Long-term flicker |
Short-time flicker measurement error £ ±5%
Long-term flicker measurement error £ ±5% |
|
Digital oscilloscope |
Instantaneous waveforms of three-phase voltage three-phase current neutral voltage and neutral current |
Maximum sampling frequency: 200KHz
Minimum sampling frequency: 100Hz |
|
Dimension |
290× 110× 55mm |
Display |
5.7 inches touch screen 320x240 color graphic LCD |
Communication interface |
USB |
Weight |
1.6kg |
Memory |
128M bit |