SBF Series Induced Voltage Test Set is utilized the saturation characteristics of magnetic circuit to remove the maximum three harmonic voltage from the device, make double frequency and double voltage test for the induction coil type electrical product by turn to turn, segment to segment and level to level test, so as to check the insulation withstand voltage level of the tested products.
Overview
(2) Meeting the needs of inductive withstanding voltage test for transformer and instrument transformers.
Models
Input capacity: 5 - 200kVA (other capacity can be customized)
Output capacity: 1 - 40kVA
Input voltage: three-phase AC380V
Output voltage: 0 ~ 300V 0 – 500V 0.800V 0-1000V can be customized. 150Hz
Input frequency: 50Hz
Output frequency: 150Hz