Overview
● After boot can immediately enter into the test
● Using the most advanced processing algorithms and digital integration technology
● Light weight and smart is portable
● New design 6 keys in the plant straight performance.
● Add the sound and light alarm function: “Beep--Beep--Beep--”.
● Add the jamming signal recognition function “Beep--Beep--Beep--”.
● The measure range extend to 0.01Ω-1200Ω.
Models
1. Series Model
Model | Jaw Specification (㎜) | Resistance range Ω) | Current range (A) | Anti-explosion function |
Store 99 groups |
Sound & light alarm | Note | ||
Round:Φ32 | Length:32×65 | 0.01-200 | 0.01-1200 | 0-20A | |||||
ETCR2000+ |
√ | √ | √ | √ | Basic Type | ||||
ETCR2000A+ |
√ | √ | √ | √ | Utility type | ||||
ETCR2000B+ |
√ | √ | √ | √ | √ | Anti-explosion type | |||
ETCR2000C+ |
√ | √ | √ | √ | √ | Multifunctional type | |||
ETCR2100+ |
√ | √ | √ | √ | Basic type | ||||
ETCR2100A+ |
√ | √ | √ | √ | Utility type | ||||
ETCR2100B+ |
√ | √ | √ | √ | √ | Anti-explosion type | |||
ETCR2100C+ |
√ | √ | √ | √ | √ | Multifunctional type |
Note: “√” means with the specification
2. Range and accuracy
Test mode | Test range | Resolution | Accuracy |
Resistance | 0.010Ω-0.099Ω | 0.001Ω | ±(1%+0.01Ω) |
0.10Ω-0.99Ω | 0.01Ω | ±(1%+0.01Ω) | |
1.0Ω-49.9Ω | 0.1Ω | ±(1%+0.1Ω) | |
50.0Ω-99.5Ω | 0.5Ω | ±(1.5%+0.5Ω) | |
100Ω-199Ω | 1Ω | ±(2%+1Ω) | |
200Ω-395Ω | 5Ω | ±(5%+5Ω) | |
400-590Ω | 10Ω | ±(10%+10Ω) | |
600Ω-880Ω | 20Ω | ±(20%+20Ω) | |
900Ω-1200Ω | 30Ω | ±(25%+30Ω) | |
*Current | 0.00mA -9.95mA | 0.05mA | ±(2.5%+1mA) |
10.0mA -99.0mA | 0.1mA | ±(2.5%+5mA) | |
100mA -300mA | 1mA | ±(2.5%+10mA) | |
0.30A-2.99A | 0.01A | ±(2.5%+0.1A) | |
3.0A-9.9A | 0.1A | ±(2.5%+0.3A) | |
10.0A-20.0A | 0.1 A | ±(2.5%+0.5A) |
3. Technical specifications
Resistance range |
0.01Ω-1200Ω |
*Current range |
0.00mA-20.0A |
Resistance resolution |
0.001Ω |
*Current resolution |
0.05mA |
Data Store |
99 groups |
Sound and light alarm |
“Beeping--beeping--beeping--” press the AL to open or shut |
Alarm critical value setting range |
Resistance:1-199Ω; *Current: 1-499mA |
Power supply |
6VDC (4 pieces No5 alkaline batteries) |
Operation environment |
-20℃-55℃;10%RH-90%RH |
LCD display |
4 bite LCD digital display 47mm(length)×28.5mm(width) |
Jaw dimension |
Long jaw 65mm×32mm: Round jaw Φ32mm |
Jaw open dimension |
Long jaw 35mm; Round jaw 32mm |
Weight |
Long jaw 1160g; Round jaw 1120g (includes battery) |
Champ dimension |
Long jaw: 285mm×85mm×56mm (Length*width*thickness) Round jaw: 260mm×90mm×66mm (Length*width*thickness) |
Anti-explosion |
Exia Ⅱ BT3 |
Protection level |
Double insulation |
Structure feature |
Clamp CT |
Shift |
Automatic shift |
Outer magnetic and electric field |
<40A/m; <1V/m |
Single measure time |
0.5 second |
Resistance measure frequency |
>1KHz |
*The tested current frequency |
50/60Hz by automatic |