DC Voltage Divider Calibration Device is composed with NRPD Series DC Standard Voltage Divider and ZGF-GW Series High Stability DC High Voltage Generator.
NRPD Series DC Standard Voltage Divider also known as high precision DC voltage divider, it is developed as a standard measurement equipment for calibrating DC voltage divider (digital high voltage meter) in high voltage measurement department or high voltage testing institute or high voltage measurement company. It can be used to test the high voltage divider with accuracy of 0.2%, 0.5%, 1%, 1.5% or lower accuracy of the electrostatic voltage meter, etc. Due to its high accuracy, it can measure relatively small changes in DC voltage, providing a reliable measure for analyzing various materials or measuring voltages or calibrating various voltages.


Overview


Models

1 NRPD Series DC Standard Voltage Divider
Specification NRPD-30 NRPD-50 NRPD-100 NRPD-200 NRPD-300 NRPD-400 NRPD-500 NRPD-800 NRPD-1000 NRPD-1200
DC rated voltage (kV) 30 50 100 200 300 400 500 800 1000 1200
Impedance (MW) 30 50 100 200 300 400 500 800 1000 1200
Voltage Ratio 105:1 104:1
Accuracy (%) 0.1%/0.05%/0.02% 0.1%/0.05%/
Annual stability ≤ 0.02%
Temperature 20℃±10℃
Relative humidity <80%RH without condensation
Dielectric Insulation oil
Height (m) 0.4 0.6 0.9 1.7 2.3 3.2 4.5 6 8 10
Length * Width 0.3 0.5 0.5 0.8 1.2 1.5 1.8 2.5 3 3.5
Weight (kg) 25 35 45 165 235 275 335 450 550 650
Output impedance (kW) 0.6/6 1/10 2/20 4/40 6/60 8 10 16 20 24
Rated output voltage (V) 0.3/3 0.5/5 1/10 2/20 3/30 4 5 8 10 12

2 ZGF-GW Series High Stability DC High Voltage Generator
Rated output DC voltage 200kV (other voltage can be customized)
Voltage is continuously adjustable in three levels
1 0 ~ 50kV
2 0 ~ 100kV
3 0 ~ 200kV
Rated output DC current 4mA
Rated output power 800W
Height of volage barrel 1.83m
Power supply AC220V± 10%50Hz
Voltage measurement error Digital display meter: ±0.5% 1 digit
Analog meter: ±2% (full scale)
Current measurement error Digital display meter ±1% 1 digit
Analog meter: ±2% (full scale)
Over-voltage setting error £1% (full scale)
Ripple factor <0.1%
Voltage adjustment rate: £ 0.05% when the power supply voltage changes ±5%
Voltage stability Warm up for 5 minutes after starting the machine. The test time for each point is 30 minutes and samples are taken at 0.5-minute intervals. £ 0.05%
1st gear: 10~20kV
2nd gear: 20~100kV
3rd gear: 40~200kV
Operation mode Intermittent use: rated load 60 minutes
Ambient temperature -15 ~ 50℃
Relative humidity £ 80% (no condensation) at 25 ℃
Altitude: ≤ 1500m £ 1500m
Weight of controller 18kg
Weight of voltage barrel 75kg
 